Lift Lever Options
Packed Lever
Series 69, 88, 740 thru 743
Packed Lift Lever Options | ||||
Item | Description | Material Options | ||
Brass | Carbon Steel | Stainless Steel | ||
1 | Handle | B16 Brass | B16 Brass/Plated | B16 Brass/Plated |
2 | Handle Screw | Steel/Plated | Steel/Plated | Steel/Plated |
3 | Cam | B16 Brass | SA479-316 SS | SA479-316 SS |
4 | Retaining Ring | Steel/Plated | 17-7 SS | 17-7 SS |
5 | O-Rings | Viton | Viton | Viton |
6 | Cam Nut | B16 Brass | SA479-316 SS | SA479-316 SS |
7 | O-Ring | PTFE | PTFE | PTFE |
8 | Hood | B16 Brass | SA108-C1018 | SA479-316 SS |
9 | Jam Nut | 18-8 Stainless | 18-8 Stainless | 18-8 Stainless |
10 | Lifter Nut | B16 Brass | SA479-316 SS | SA479-316 SS |
11 | Hood Seal | PTFE | PTFE | PTFE |
12* | Plug | 18-8 Stainless | 18-8 Stainless | 18-8 Stainless |
13* | Washer | PTFE | PTFE | PTFE |
14* | Gag Screw | 18-8 Stainless | 18-8 Stainless | 18-8 Stainless |
*Gag Screw Option
Open
Lever
(Standard on all ASME valves)
Series 69, 88, 560 thru 573, 740 thru 743
Open Lift Lever Options | ||||
Item | Description | Material Options | ||
Brass | Carbon Steel | Stainless Steel | ||
1 | Handle | C1018/Plated | C1018/Plated | C1018/Plated |
2 | Hood | Anodized Alum. | Anodized Alum. | Anodized Alum. |
3 | Lifter Nut | B16 Brass | SA479-316 SS | SA479-316 SS |
4 | Jam Nut | 18-8 Stainless | 18-8 Stainless | 18-8 Stainless |
5 | Lift Lever Pin | B16 Brass | SA479-316 SS | SA479-316 SS |
6* | Spring | Optional Anti-Vibration Spring | Stainless |
*Anti-Vibration Spring Option
Easy Test Lever
Available on:
Series 560 thru 573
Easy Test Lever Options | ||||
Item | Description | Material Options | ||
Brass | Carbon Steel | Stainless Steel | ||
1 | Handle | C1018/Plated | C1018/Plated | C1018/Plated |
2 | Hood | B16 | B16 | B16 |
3 | Lift Washer | B16 Brass | B16 Brass | B16 Brass |
4 | Cotter Pin | 18-8 Stainless | 18-8 Stainless | 18-8 Stainless |
5 | Spring Post | B16 | B16 | B16 |
Lifting Device as required by the ASME
ASME Section VIII: UG136(3)
Each pressure relief valve on air, water at the valve inlet that
exceeds 140°F (60°C), excluding over-pressure or relief
events, or steam service shall have a substantial lifting device
which when activated will release the seating force on the disk
when the pressure relief valve is subjected to a pressure of at
least 75% of the set pressure of the valve.
The lift lever may be omitted providing:
1. The user has a documented procedure
and an associated implementation program for the periodic removal
of the relief valve for inspection, testing, and repair.
2. The user specifies that no test lever be supplied.
3. The user shall obtain permission to omit the lifting lever
(device) from the authority having jurisdiction over the
installation of pressure vessel.
These rules apply to valves installed in ASME Section VIII applications.
All valves used in ASME Section I (Boiler) applications require lifting levers except for those valves used in organic fluid vaporizer service.