NB18 Report |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Tuesday, September 10, 2024 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Aquatrol, Incorporated (AQT) |
Nameplate Abbreviation: Aquatrol |
|
Elburn, IL 60119United States |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
This Company Manufactures or Assembles: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
120, 121, 125, 126 |
NBCert # |
02068 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2024 |
|
Design Type |
|
[Safety Relief Valve] 120, 121, 125, 126 Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on February 3, 1982 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 1.037 SCFM/PSIA; (alternate medium): 2.910 PPH/PSIA Media - Test: Air/Gas; Certified: Air, Gas, Steam Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.5-1 NPS |
.75, top NPS |
|
0.75 in |
0.045 in |
15-200 psi |
Air |
UV |
|
0.5-1 NPS |
.75, top NPS |
|
0.75 in |
0.045 in |
15-200 psi |
Steam |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
130, 132, 133, 135 |
NBCert # |
02079 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 130, 132, 133, 135 Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 15, 1980 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 0.403 SCFM/PSIA; (alternate medium): 1.130 PPH/PSIA Media - Test: Air/Gas; Certified: Air, Gas, Steam Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.25-0.5 NPS |
.5, Top NPS |
|
0.5 in |
0.024 in |
15-200 psi |
Air |
UV |
|
0.25-0.5 NPS |
.5, Top NPS |
|
0.5 in |
0.024 in |
15-200 psi |
Steam |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
140-A |
NBCert # |
02114 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
02/22/2031 |
|
Design Type |
|
[Safety Relief Valve] 140-A Capacity Tests: Sec. UV at National Board Testing Lab on August 20, 2018 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 0.924 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.25-0.5 NPS |
|
0.0604 in² |
0.281 in |
0.09 in |
15-450 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
140-B |
NBCert # |
02125 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
02/22/2031 |
|
Design Type |
|
[Safety Relief Valve] 140-B Capacity Tests: Sec. UV at National Board Testing Lab on August 20, 2018 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 1.487 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.375-0.75 NPS |
|
0.0837 in² |
0.39 in |
0.12 in |
15-450 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
560, 570 |
NBCert # |
02080 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV, V |
01/19/2028 |
|
Design Type |
|
[Safety Valve] 560, 570 Capacity Tests: Sec. UV, V at National Board Testing Lab on November 10, 2005 Method of Establishing Relieving Capacity: Flow Capacity, K Certified Value: 0.856 Unitless Media - Test: Steam; Certified: Air, Gas, Steam Set Pressure Definition: Pop Blowdown Characteristics: Adjustable (Dual Ring) Flow Area Configuration: Nozzle/Full Lift Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.5-0.75 NPS |
.75 NPS |
0.125 in² |
[D] 0.4 in |
0.1 in |
15-300 psi |
Steam |
UV, V |
|
0.5-0.75 NPS |
.75 NPS |
0.125 in² |
[D] 0.4 in |
0.1 in |
15-300 psi |
Air |
UV |
|
0.75-1 NPS |
1 NPS |
0.221 in² |
[E] 0.53 in |
0.132 in |
15-300 psi |
Steam |
UV, V |
|
0.75-1 NPS |
1 NPS |
0.221 in² |
[E] 0.53 in |
0.132 in |
15-300 psi |
Air |
UV |
|
1-1.25 NPS |
1.25 NPS |
0.352 in² |
[F] 0.67 in |
0.167 in |
15-300 psi |
Steam |
UV, V |
|
1-1.25 NPS |
1.25 NPS |
0.352 in² |
[F] 0.67 in |
0.167 in |
15-300 psi |
Air |
UV |
|
1.25-1.5 NPS |
1.5 NPS |
0.567 in² |
[G] 0.85 in |
0.212 in |
15-300 psi |
Steam |
UV, V |
|
1.25-1.5 NPS |
1.5 NPS |
0.567 in² |
[G] 0.85 in |
0.212 in |
15-300 psi |
Air |
UV |
|
1.5-2 NPS |
2 NPS |
0.899 in² |
[H] 1.07 in |
0.267 in |
15-300 psi |
Steam |
UV, V |
|
1.5-2 NPS |
2 NPS |
0.899 in² |
[H] 1.07 in |
0.267 in |
15-300 psi |
Air |
UV |
|
2-2.5 NPS |
2.5 NPS |
1.463 in² |
[J] 1.365 in |
0.41 in |
15-300 psi |
Steam |
UV, V |
|
2-2.5 NPS |
2.5 NPS |
1.463 in² |
[J] 1.365 in |
0.41 in |
15-300 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
88A, 89A |
NBCert # |
02002 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 88A, 89A Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 15, 1980 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 0.644 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.5 NPS |
.75 NPS |
|
0.5 in |
0.036 in |
15-250 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
88B, 89B |
NBCert # |
02013 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 88B, 89B Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 15, 1980 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 0.930 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.75 NPS |
1 NPS |
|
0.75 in |
0.04 in |
15-250 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
88C, 89C |
NBCert # |
02024 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 88C, 89C Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 14, 1980 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 2.274 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1 NPS |
1.25 NPS |
|
1 in |
0.075 in |
15-250 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
88D, 89D |
NBCert # |
02035 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 88D, 89D Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 14, 1980 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 3.504 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.25 NPS |
1.5 NPS |
|
1.25 in |
0.086 in |
15-250 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
88E, 89E |
NBCert # |
02046 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 88E, 89E Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 14, 1980 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 4.900 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1.5 NPS |
2 NPS |
|
1.5 in |
0.1 in |
15-250 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
88F, 89F |
NBCert # |
02057 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
11/26/2030 |
|
Design Type |
|
[Safety Relief Valve] 88F, 89F Capacity Tests: Sec. UV at National Board Testing Lab (Picaway) on October 14, 1981 Method of Establishing Relieving Capacity: Flow Capacity, 4-Device Method Certified Value: 7.404 SCFM/PSIA Media - Test: Air/Gas; Certified: Air, Gas Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Curtain Area Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
2 NPS |
2.5 NPS |
|
2 in |
0.12 in |
15-250 psi |
Air |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
Series 740 |
NBCert # |
02091 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
02/11/2031 |
|
Design Type |
|
[Safety Relief Valve] Series 740 Capacity Tests: Sec. UV at National Board Testing Lab on November 21, 2012 Method of Establishing Relieving Capacity: Flow Capacity, K Certified Value: 0.878 Unitless Media - Test: Air/Gas, Steam; Certified: Air, Gas, Steam Set Pressure Definition: Pop Blowdown Characteristics: Fixed Flow Area Configuration: Nozzle/Full Lift Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.5-1 NPS |
0.75, 1 NPS |
0.125 in² |
[D] 0.4 in |
0.105 in |
15-1500 psi |
Air |
UV |
|
0.5-1 NPS |
0.75, 1 NPS |
0.125 in² |
[D] 0.4 in |
0.105 in |
15-300 psi |
Steam |
UV |
|
0.5-1.25 NPS |
1, 1.25 NPS |
0.217 in² |
[E] 0.526 in |
0.135 in |
15-1500 psi |
Air |
UV |
|
0.5-1.25 NPS |
1, 1.25 NPS |
0.217 in² |
[E] 0.526 in |
0.135 in |
15-300 psi |
Steam |
UV |
|
0.75-1.5 in |
1, 1.25 NPS |
0.217 in² |
[E] 0.526 in |
0.135 in |
15-1500 psi |
Air |
UV |
|
0.75-1.5 in |
1, 1.25 NPS |
0.217 in² |
[E] 0.526 in |
0.135 in |
15-300 psi |
Steam |
UV |
|
1-1.5 NPS |
1.5 NPS |
0.353 in² |
[F] 0.67 in |
0.17 in |
15-750 psi |
Air |
UV |
|
1-1.5 NPS |
1.5 NPS |
0.353 in² |
[F] 0.67 in |
0.17 in |
15-300 psi |
Steam |
UV |
|
1-2 in |
1.5 NPS |
0.353 in² |
[F] 0.67 in |
0.017 in |
15-750 psi |
Air |
UV |
|
1-2 in |
1.5 NPS |
0.353 in² |
[F] 0.67 in |
0.017 in |
15-300 psi |
Steam |
UV |
|
1.25-2 NPS |
2 NPS |
0.554 in² |
[G] 0.84 in |
0.215 in |
15-700 psi |
Air |
UV |
|
1.25-2 NPS |
2 NPS |
0.554 in² |
[G] 0.84 in |
0.215 in |
15-300 psi |
Steam |
UV |
|
1.5-2.5 NPS |
2, 2.5 NPS |
0.923 in² |
[H] 1.084 in |
0.28 in |
15-600 psi |
Air |
UV |
|
1.5-2.5 NPS |
2, 2.5 NPS |
0.923 in² |
[H] 1.084 in |
0.28 in |
15-300 psi |
Steam |
UV |
|
2-3 NPS |
3 NPS |
1.418 in² |
[J] 1.344 in |
0.34 in |
15-600 psi |
Air |
UV |
|
2-3 NPS |
3 NPS |
1.418 in² |
[J] 1.344 in |
0.34 in |
15-300 psi |
Steam |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Design Name: |
Series 740 (Liquid) |
NBCert # |
02103 |
|
Manufacturer/Assembler |
Designators |
Expiration Date |
|
Manufacturer |
UV |
02/11/2031 |
|
Design Type |
|
[Safety Relief Valve] Series 740 (Liquid) Capacity Tests: Sec. UV at National Board Testing Lab on November 20, 2012 Method of Establishing Relieving Capacity: Flow Capacity, K Certified Value: 0.791 Unitless Media - Test: Liquid; Certified: Liquid Set Pressure Definition: First Steady Stream Flow Area Configuration: Nozzle/Full Lift Designed by: Aquatrol, Incorporated {AQT} |
|
|
|
|
|
|
|
|
|
|
|
|
Inlet Size |
Outlet Size |
Flow Area |
Orifice [designator] dia. |
Lift |
Set Pressure Range |
Media |
Designator |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
0.5-1 NPS |
0.75, 1 NPS |
0.125 in² |
[D] 0.4 in |
0.105 in |
15-1500 psi |
Water |
UV |
|
0.75-1.25 NPS |
1, 1.25 NPS |
0.217 in² |
[E] 0.526 in |
0.135 in |
15-1500 psi |
Water |
UV |
|
0.75-1.5 in |
1, 1.25 NPS |
0.217 in² |
[E] 0.526 in |
0.135 in |
15-1500 psi |
Water |
UV |
|
1-1.5 NPS |
1.5 NPS |
0.353 in² |
[F] 0.67 in |
0.17 in |
15-750 psi |
Water |
UV |
|
1-2 in |
1.5 NPS |
0.353 in² |
[F] 0.67 in |
0.017 in |
15-750 psi |
Water |
UV |
|
1.25-2 NPS |
2 NPS |
0.554 in² |
[G] 0.84 in |
0.215 in |
15-700 psi |
Water |
UV |
|
1.5-2.5 NPS |
2, 2.5 NPS |
0.923 in² |
[H] 1.084 in |
0.28 in |
15-600 psi |
Water |
UV |
|
2-3 NPS |
3 NPS |
1.418 in² |
[J] 1.344 in |
0.34 in |
15-600 psi |
Water |
UV |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Page 1 of 1 |
|